ClickCease

Delta Faucet RP19804 Monitor 1300 Series and 1400 Series Cartridge

UPC:
034449245708
Condition:
New
No reviews yet Write a Review
$59.97

Description

Delta Faucet RP19804 Monitor 13 (1300) and 14 (1400) Series Cartridge Assembly

Over time, just about any shower can develop a leak, seals can dry out, and calcium and mineral deposits can build up, but this is a relatively easy problem to fix, if you know how.  Today, we are going to show you how to replace the cartridge on your delta shower.  We’ll also show you how to replace the seats in springs which is a lower cost alternative on some shower models.  Before getting started though, make sure you have quality replacement parts for your delta shower.  If you need some help in determining your type of fixture, visit Delta’s website at deltafaucet.com.

If your 13/14 series shower was shipped before March of 2006, you will need to order part number RP19804.  These are the pre-multi choice showers, and you can identify them by the white cartridge cap.  Now if you have one of the multi-choice series of showers from March 2006 and after, you will need to order Part number RP46074, which has a grey cartridge cap.  For more information, check the cartridge reference sheet in the instruction manual.

Extra Information

Brand:
Delta
MPN::
RP19804

Warranty Information

Delta Faucet RP19804 Monitor 13/14 Series Cartridge Assembly Begin by turning off the water supply to the shower. Since most showers don’t have individual supply valves, you will need to shut off the water to the entire house. Cover the drain to make sure you don’t inadvertently drop any parts down the drain. 1. Using an allen wrench loosen the set screw holding the handle in place. Now remove the handle and then the trims leave in spacer. 2. Next you will see the valve cartridge which is held in place by a bonnet nut. Use a strap wrench or a pair of channel-lock pliers to remove the bonnet nut and set it aside. 3. Remove the valve cartridge by grabbing it firmly, and wiggling it back and forth as you pull it out. As you do, any remaining water in the lines will pour out as well. 4. Reinstall the cartridge making sure the hot side marking is on the side of the valve the hot water comes from, this is typically the left. 5. Line up the keys on the side with the slots in the valve, put the bonnet nut back on, and hand tighten fully. 6. Now reassemble the components of the faucet. See Below For More Detailed Instructions: 1. Read complete instructions and familiarize yourself with the illustrations before beginning. Plumber installation is recommended. 2. WARNING! SHUT OFF WATER SUPPLIES BEFORE DISASSEMBLING THE TUB SHOWER VALVE. 3. Remove handle. 4. CAUTION! Mark the Rotational Limit Stop “RLS” (A) with a pen or pencil on the raised rib that aligns with the groove on the brass stop (B). NOTE: after installing the new cartridge, its RLS must be in the same position (if this position provided the correct handle rotation previously). See important information and RLS Adjustment on the back of this sheet (Steps 4.1, 4.2 and 4.3). 5. CAUTION! Pull off the RLS (A) and note the position of the raised stop (C) on the cap assembly that says “hot side”. The cartridge must always be put back in this same position. The raised stop should always be located on the hot water inlet side so cold water will flow first. For normal installations, the raised stop will be on the left. 6. Pull outside sleeve (D) off. Then, if necessary, slide the sleeve O-Ring (E) toward you until it stops at the raised brass section (F) on the tub/shower body. Do not pull the sleeve O-Ring over the raised brass section.NOTE: when the sleeve is re-installed, it will slide on this O-Ring. 7. BE SURE WATER SUPPLIES ARE SHUT OFF! 8. Unscrew the brass bonnet (G). 9. Do not pry the cartridge out of the body with a screwdriver. Re-install the handle on brass stem (H) and rotate counterclockwise while lifting the cartridge out of the two notches on the sides of the body. 1CAUTION! Do not twist the Cap and Lower Housing of the New Cartridge to take it apart. If they are separated for any reason, be sure they are locked back together by twisting them together until they snap back together.WARNING! Never take the Lower Housing Apart. 11. Install the cartridge with the raised stop on the cap (C) on the hot water inlet side (see Step 5). 12. Re-assemble the brass bonnet (G). 13. Slide on the outside sleeve (D) (see Step 6). 14. Remove and throw away the black retention plug (not illustrated) from the brass stem (H) at the top of the new cartridge. 15. Check for proper installation of the RLS (A) on the new cartridge by following Steps 4.1, 4.2 and 4.3 (on reverse side). 16. Re-install the handle then proceed to Step 17. 17. FLUSH YOUR SYSTEM. Turn handle to full on “hot and cold mix” position. Turn on water supplies. Check for leaks and let supply lines flush for one minute without moving handle. If you have a showerhead, divert water to it and flush for 30 seconds. This will remove any debris from the supply lines that can damage internal parts of the faucet and create leaks. BE SAFE! After you have finished the repair, turn on tub/shower valve to make sure COLD WATER FLOWS FIRST. If not, see Step 5. 4.1 CAUTION: After installing the new cartridge, remove the RLS (A). If the raised stop (C) on the cap assembly is located on the left (see Step 5) rotate the brass stop (B) to the bottom left so it is positioned below the raised stop (C) as illustrated in the Rotational Limit Stop Adjustment box. If the raised stop (C) on the cap assembly is located on the right, rotate the brass stop (B) to the top right so it is positioned above the raised stop (C). 4.2 IMPORTANT! The first position of the Rotational Limit Stop (RLS) (A) is that position that restricts the rotation of the handle (stem) the most and is at the maximum counterclockwise setting. According to industry standards, the maximum allowable temperature of the water exiting from the valve is 120°F**. This temperature may vary in your local area. The RLS may need to be readjusted manually if either of the inlet water temperatures change. For instance, during the winter, the cold water temperature is colder than it is during the summer, which could result in varying outlet temperatures. Typical temperature for a comfortable bath or shower is between 90°-110°F. 4.3 ADJUSTING THE ROTATIONAL LIMIT STOP: • Let the water run so that cold is as cold as it will get and hot water is as hot as it will get. Place handle back on stem and rotate fully counterclockwise to the hottest position. • Place a thermometer in a plastic tumbler and hold in the water stream. If the water temperature is above 110°-120°F**, the Rotational Limit Stop (RLS) (A) must be rotated counterclockwise to decrease temperature. In that case, remove the RLS and replace it one tooth counterclockwise for every 6°F (approximate) reduction in temperature that must be made. Repeat as necessary. • MAKE SURE COLD WATER FLOWS FROM THE VALVE FIRST. **MAKE SURE WATER (AT THE HOTTEST FLOW) DOES NOT EXCEED THE TEMPERATURE ALLOWED BY YOUR PLUMBING CODES (110° OR 120°F). If the water in your area has lime, rust, sand or other contaminants in it, your cartridge will require periodic inspection. To inspect the cartridge, after shutting off the water supplies, turn the handle to the “on” position before following Steps 2 - 10 to disassemble. The cartridge must be in the full “on” position before inspection. If it is in the “off” position, this test will not work. After removing the cartridge, shake it vigorously. If there is a rattling sound, it is functional and can be reinstalled following Steps 11-17. If there is no rattle: • Rotate the RLS to be sure it is in the “on” position; • Rap the lower housing in the palm of your hand, or • Replace the complete cartridge (RP19804). Your tub/shower valve is designed to minimize the effects of outlet water temperature changes due to inlet pressure changes, commonly caused by dishwashers, washing machines, toilets and the like. It may not provide protection from hot water burns when there is a failure of other temperature controlling devices elsewhere in the plumbing system. If changes occur and you are not sure how to make the necessary RLS (A) adjustments, consult the installation instruction sheet provided with your tub/shower valve or call 1-800-345-DELTA (3358).

Videos